2sx5601-1ba20 1-phas.-anpassungs- transformator, 1,5 kva, ip 00 pri. 500-480-460-440-415-400- 380 v, 50...60 hz sec. 230 v, 6,5 a 2sx5601-1ba25 1-phas.-anpassungs- transformator, 1,5 kva, ip 54 pri. 500-480-460-440-415-400- 380 v, 50...60 hz sec. 230 v, 6,5 a 2sx5601-1ca20 1-phas.-anpassungs- transformator, 1,5 kva, ip 00 pri. 690-660 v, 50...60 hz sec. 230 v, 6,5 a 2sx5601-1ca25 1-phas.-anpassungs- transformator, 1,5 kva, ip 54 pri. 690-660 v, 50...60 hz sec. 230 v, 6,5 a 2sx5602-3cb40 3-phas.-anpassungs- transformator, 3,81 kva, ip 00 pri. 690-660 v, 50...60 hz sec. 400 v, 5,5 a 2sx5602-3cb45 3-phas.-anpassungs- transformator, 3,81 kva, ip 54 pri. 690-660 v, 50...60 hz sec. 400 v, 5,5 a 2sx5602-3cc40 3-phas.-anpassungs- transformator, 6,93 kva, ip 00 pri. 690-660 v, 50...60 hz sec. 400 v, 10 a 2sx5602-3cc45 3-phas.-anpassungs- transformator, 6,93 kva, ip 54 pri. 690-660 v, 50...60 hz sec. 400 v, 10 a 2sx5602-3cd40 3-phas.-anpassungs- transformator, 11,1 kva, ip 00 pri. 690-660 v, 50...60 hz sec. 400 v, 16 a 2sx5602-3cd45 3-phas.-anpassungs- transformator, 11,1 kva, ip 54 pri. 690-660 v, 50...60 hz sec. 400 v, 16 a 2sx5700-0lr00 lack-reparaturset ral7030 18 ml pinselflaeschchen 2sx9000-0aw16 elektronischer stellungsmelder mit welle 16 mm (c74451-a1128-a11); 2sx9000-0aw33 elektronischer stellungsmelder mit welle 33 mm (c74451-a1128-a1); 2sx9000-1mr00 elektronischer stellungsmelder mit rueckholfeder und mit anschlag (c73451-a383-a2); 2sx9000-1wr00 elektronischer stellungsmelder ohne rueckholfeder und ohne anschlag (nma:2650112500) / (c73451-a383-a1) / (r410134); 2sy5001-0....-.... elektronikeinheit lackiert ral7030 fuer steuerantriebe; 2sy5001-5....-.... electronics unit painted ral7030 for modulating duty with actuator-neutral also applicable for on-off actuator 2sy5009-0mm00 adapter electrical connection sipos 5 micromaster for sipos 5 flash electronics unit; 2sy5012-0lb15 power control pc board for small electronics unit (motor 1.5 kw) 2sy5012-0lb75 power control pc board for small electronics unit (motor 750 w) 2sy5012-1lb55 power control pc board for big electronics unit (motor from 3 kw); 2sy5013-1mb10 modbus rtu-platine 1-kanalig, max. 38.400 baud, mit montageanleitung; 2sy5013-1pb10 profibus pc board single channel 1.5mbaud,with mounting instruction 2sy5013-2mb10 modbus rtu-platine 2-kanalig, max. 38.400 baud, mit montageanleitung; 2sy5013-2pb10 profibus pc board double channel 1.5mbaud,with mounting instruction 2sy5014-0rk10 relay board, with mounting instruction 2sy5016-1sb00 control pc board ecotron wiith mounting instruction 2sy5016-2sb00 control pc board profitron wiith mounting instruction 2sy5017-0gt01 connection pcb galvanical separation for position actual value 2sy5017-0gt02 connection pcb galvanical separation for position actual value and position setpoint 2sy5017-0lw00 profibus-busanschlussplatine (anschluss ueber lichtwellen- leiter), komplett mit kabelbaeumen; 2sy5017-0pa00 profibus bus termination pcb complete with wiring harnesses 2sy5018-0pm15 power modul for small electronis unit, complete with thermal conduction paste mounting instruction and mounting parts (motor up to 1.5kw) 2sy5018-0pm55 power modul for big electronis unit, complete with thermal conduction paste mounting instruction and mounting parts (motor from 3kw) 2sy5030-2ah00 connection cover for direct connection, painted ral7030 complett with caps, o-ring and mounting parts 2sy5030-2ah01 connection cover for round plug 1-phas., painted ral7030, incl. plug element with contact sockets, complett with caps o-ring and mounting parts 2sy5030-2ah02 connection cover for round plug 3-phas., painted ral7030, incl. plug element with contact sockets, complett with caps o-ring and mounting parts 2sy5030-2ah03 connection cover for round plug 1-phas. with relay board painted ral7030, incl. plug element with contact sockets complett with caps, o-ring and mounting parts 2sy5030-2ah04 connection cover for round plug 3-phas. with relay board painted ral7030, incl. plug element with contact sockets complett with caps, o-ring and mounting parts 2sy5033-0gh11 connection galvanical separa- tion for position actual value painted ral7030; for 1 x ac230v complete mounted with connec- tion cover, incl. plug element with contact sockets, o-rings and mounting parts 2sy5033-0gh12 connection galvanical separa- tion for position actual value and position setpoint, painted ral7030; for 1 x ac 230v; com- plete mounted with connection cover, incl. plug element with contact sockets, o-rings and mounting parts 2sy5033-0gh31 connection galvanical separa- tion for position actual value painted ral7030; for 3 x ac440- 460v; complete mounted with connection cover, incl. plug element with contact sockets o-rings and mounting parts 2sy5033-0gh32 connection galvanical separa- tion for position actual value and position setpoint, painted ral7030; for 3 x ac 400-460v; complete mounted with connec- tion cover, incl. plug element with contact sockets, o-rings and mounting parts 2sy5033-0lw10 profibus - anschluss ueber lichtwellenleiter, lackiert ral7030, fuer 1 x ac 230v, komplett montiert mit busan- schlussplatine und anschluss- deckel, inkl. steckerelement mit kontaktbuchsen, o-ringen und befestigungselementen; 2sy5033-0lw30 profibus - anschluss ueber lichtwellenleiter, lackiert ral7030, fuer 3 x ac 400-460v, komplett montiert mit busan- schlussplatine und anschluss- deckel, inkl. steckerelement mit kontaktbuchsen, o-ringen und befestigungselementen; 2sy5033-0ph10 profibus connection, painted ral7030; for 1 x ac 230v; complete mounted with bus termination pcb and profibus connection cover, incl: plug element with contact sockets o-rings and mounting parts 2sy5033-0ph30 profibus connection, painted ral7030; for 3 x ac 400-460v; complete mounted with bus termination pcb and profibus connection cover, incl: plug element with contact sockets o-rings and mounting parts 2sy5033-1gh11 anschluss galvanische trennung fuer stellungsistwert, lackiert ral7030, 1-phas. mit relais- karte, kpl. montiert mit anschlussdeckel, inkl. steckerelement mit kontaktbuch- sen, o-ringen u. befestigungs- elementen 2sy5033-1gh12 anschluss galvanische trennung fuer stellungsistwert u. -soll- wert, lackiert ral7030, 1-phas. mit relaiskarte, kpl. montiert mit anschlussdeckel, inkl. steckerelement mit kontaktbuch- sen, o-ringen u. befestigungs- elementen 2sy5033-1gh31 anschluss galvanische trennung fuer stellungsistwert, lackiert ral7030, 3-phas. mit relais- karte, kpl. montiert mit anschlussdeckel, inkl. steckerelement mit kontaktbuch- sen, o-ringen u. befestigungs- elementen 2sy5033-1gh32 anschluss galvanische trennung fuer stellungsistwert u. -soll- wert, lackiert ral7030, fuer 3 x ac 400-460v, kpl. montiert mit anschlussdeckel, inkl. steckerelement mit kontaktbuch- sen, o-ringen u. befestigungs- elementen; 2sy5034-0sr11 plug element internal connec- tion, with contact pins 1-phas., for round plug; complete with wiring harnesses and mounting parts 2sy5034-0sr12 plug element internal connec- tion, with contact pins 1-phas., for round plug with relay board; complete with wiring harnesses and mounting parts 2sy5034-0sr13 plug element internal connec- tion, with contact pins 1-phas., for profibus 1-channel complete with wiring harnesses and mounting parts 2sy5034-0sr14 plug element internal connec- tion, with contact pins 1-phas., for profibus 2-channel complete with wiring harnesses and mounting parts 2sy5034-0sr31 plug element internal connec- tion, with contact pins 3-phas., for round plug; complete with wiring harnesses and mounting parts 2sy5034-0sr32 plug element internal connec- tion, with contact pins 3-phas., for round plug with relay board; complete with wiring harnesses and mounting parts 2sy5034-0sr33 plug element internal connec- tion, with contact pins 3-phas., for profibus 1-channel complete with wiring harnesses and mounting parts 2sy5034-0sr34 plug element internal connec- tion, with contact pins 3-phas., for profibus 2-channel complete with wiring harnesses and mounting parts 2sy5035-1sr40 plug element for electronic connection, with contact sockets; complete with wiring harnesses and mounting parts 2sy5036-1sr50 plug element for gear unit connection, with contact pins; complete with mounting parts 2sy5037-0pa00 connection cover profibus/ galvanical separation, painted ral7030; complete with o-ring and mounting parts 2sy5041-3ed01 electronics housing cover complete with operating foil o-ring and mounting parts; for ecotron, small electronics unit (motor to 1.5 kw) 2sy5041-3ed34 electronics housing cover complete with operating foil o-ring and mounting parts; for ecotron, big electronics unit (motor from 3 kw) 2sy5041-3mc01 deckel fuer elektronikgehaeuse ecotron aus metall, komplett mit drucktasten, bedienfolie, o-ring und befestigungselemen- ten, fuer kleine elektronikein- heit (motor bis 1,5 kw); 2sy5041-3mc34 deckel fuer elektronikgehaeuse ecotron aus metall, komplett mit drucktasten, bedienfolie, o-ring und befestigungselemen- ten, fuer grosse elektronikein- heit (motor ab 3 kw); 2sy5041-4ed01 electronics housing cover complete with operating foil o-ring and mounting parts; for profitron, small electronics unit (motor to 1.5 kw) 2sy5041-4ed34 electronics housing cover complete with operating foil o-ring and mounting parts; for profitron, big electronics unit (motor from 3 kw) 2sy5041-4mc01 deckel fuer elektronikgehaeuse profitron aus metall, komplett mit drucktasten, bedienfolie, o-ring und befestigungselemen- ten, fuer kleine elektronikein- heit (motor bis 1,5 kw); 2sy5041-4mc34 deckel fuer elektronikgehaeuse profitron aus metall, komplett mit drucktasten, bedienfolie, o-ring und befestigungselemen- ten, fuer grosse elektronikein- heit (motor ab 3 kw); 2sy5042-1eg10 electronics housing, painted ral7030, for small electronics unit (motor to 1.5 kw); 2sy5042-3eg10 electronics housing, painted ral7030, for big electronics unit (motor from 3 kw); 2sy5055-0st10 printed circuit board plugs complete set for power and control wire connections incl. markers 2sy5056-0cb01 contact sockets (10 pieces) screw contacts, 25a, to 6mm2 cu, for grounding cable 2sy5056-0cb02 contact sockets (10 pieces) screw contacts, 25a, to 6mm2 cu, for power wire connection 2sy5056-0cb03 contact sockets (10 pieces) screw contacts, 16a, to 2.5mm2 sn, for control wire connection tin plated 2sy5056-0cb04 contact sockets (10 pieces) screw contacts, 16a, to 2.5mm2 au, for control wire connection gold plated 2sy5056-0cs01 contact pins (10 pieces), crimp contacts, 25a, 2.5 to 4mm2, cu for grounding cable and power wire connection, big electronics unit (motor from 3kw) 2sy5056-0cs02 contact pins (10 pieces), crimp contacts, 25a, 0.75 to 1.5mm2 cu, for power wire connection small electronics unit (motor to 1.5kw) 2sy5056-0cs03 contact pins (10 pieces), crimp contacts, 16a, 0.20 to 0.55mm2 sn, for control wire connection tin plated 2sy5056-0cs04 contact pins (10 pieces), crimp contacts, 16a, 0.20 to 0.55mm2 au, for control wire connection gold plated 2sy5056-0cs05 contact pins (10 pieces), crimp contacts, 16a, 0.75 to 1.5mm2 au, for travel sensot for modulating duty, gold plated 2sy5210-0ge11 gear unit without add-on components, for standard painted ral7030, flange f10 assembled and filed with durable gear oil; for 2sa501/2 5-40 and 10-80 1/min; 2sc500/1/2/3/4 2sy5210-0ge12 gear unit without add-on components, for standard painted ral7030, flange f10 assembled and filed with durable gear oil; for 2sa501 20-112u/min; 2sa502 20-160 u/min 2sy5210-0ge13 gear unit without add-on components, for standard painted ral7030, flange g0 assembled and filed with durable gear oil; for 2sa501/2 5-40 and 10-80 1/min; 2sy5210-0ge14 gear unit without add-on components, for standard painted ral7030, flange g0 assembled and filed with durable gear oil; for 2sa501/2 20-160 1/min; 2sy5210-0ge31 gear unit without add-on components, for standard painted ral7030, flange f14 assembled and filed with durable gear oil; for 2sa503/4 5-40 and 10-80 1/min; 2sc505/6 2sy5210-0ge32 gear unit without add-on components, for standard painted ral7030, flange f14 assembled and filed with durable gear oil; for 2sa503/4 20-160 1/min; 2sy5210-0ge41 gear unit without add-on components, for standard painted ral7030, flange f16 assembled and filed with durable gear oil; for 2sa505 5-40 and 10-80 1/min; 2sa506 5-40 1/min; 2sa507 2.5- 20 1/min, 2sa508 1.25-10 1/min 2sy5210-0ge42 gear unit without add-on components, for standard painted ral7030, flange f16 assembled and filed with durable gear oil; for 2sa505 20-112 1/min; 2sa506 10-56 1/min; 2sa507 5-28 1/min; 2sa508 2.5-14 1/min 2sy5210-0gk11 gear unit without add-on components, for standard painted ral7030, flange f10 assembled and filed with durable gear oil; for 2sa501/2 5-40 and 10-80 1/min; 2sc500/1/2/3/4 2sy5210-0gk12 gear unit without add-on components, for standard painted ral7030, flange f10 assembled and filed with durable gear oil; for 2sa501/2 20-160 1/min; 2sy5210-0gk13 gear unit without add-on components, for standard painted ral7030, flange g0 assembled and filed with durable gear oil; for 2sa501/2 5-40 and 10-80 1/min; 2sy5210-0gk14 gear unit without add-on components, for standard painted ral7030, flange g0 assembled and filed with durable gear oil; for 2sa501/2 20-160 1/min; 2sy5210-0gk31 gear unit without add-on components, for standard painted ral7030, flange f14 assembled and filed with durable gear oil; for 2sa503/4 5-40 and 10-80 1/min; 2sc505/6 2sy5210-0gk32 gear unit without add-on components, for standard painted ral7030, flange f14 assembled and filed with durable gear oil; for 2sa503/4 20-160 1/min; 2sy5210-0gk41 gear unit without add-on components, for standard painted ral7030, flange f16 assembled and filed with durable gear oil; for 2sa505 5-40 and 10-80 1/min; 2sa506 5-40 1/min; 2sa507 2.5- 20 1/min, 2sa508 1.25-10 1/min 2sy5210-0gk42 gear unit without add-on components, for standard painted ral7030, flange f16 assembled and filed with durable gear oil; for 2sa505 20-112 1/min; 2sa506 10-56 1/min; 2sa507 5-28 1/min; 2sa508 2.5-14 1/min 2sy5210-5ge11 gear unit without add-on components, for modulating duty, painted ral7030, flange f10, assembled and filed with durable gear oil; for 2sa551/2; 2sb551/2; 2sc550/1/2 2sy5210-5ge13 gear unit without add-on components, for modulating duty, painted ral7030, flange g0, assembled and filed with durable gear oil; for 2sa551/2;
|