6sl3211-0ab21-1ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 1,1kw; vt: 1,1kw ct-ueberlast: 150% 60s 160 x 140 x 142 (hxbxt) schutzart ip20 umgebungstemperatur -10+50grd c ohne bop ohne analogeingang 6sl3211-0ab21-5aa0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 1,5kw; vt: 1,5kw ct-overload: 150% 60s 160 x 140 x 142 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without rs485-interface 6sl3211-0ab21-5aa1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz analogeingang ct: 1,5kw; vt: 1,5kw ct-ueberlast: 150% 60s 160 x 140 x 142 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne rs485-interface 6sl3211-0ab21-5ab0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 1,5kw; vt: 1,5kw ct-overload: 150% 60s 160 x 140 x 142 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without an 6sl3211-0ab21-5ab1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 1,5kw; vt: 1,5kw ct-ueberlast: 150% 60s 160 x 140 x 142 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne analog 6sl3211-0ab21-5ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 1,5kw; vt: 1,5kw ct-overload: 150% 60s 160 x 140 x 142 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without rs485-interface 6sl3211-0ab21-5ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 1,5kw; vt: 1,5kw ct-ueberlast: 150% 60s 160 x 140 x 142 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne rs485-interface 6sl3211-0ab21-5ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 1,5kw; vt: 1,5kw ct-overload: 150% 60s 160 x 140 x 142 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without analog in 6sl3211-0ab21-5ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 1,5kw; vt: 1,5kw ct-ueberlast: 150% 60s 160 x 140 x 142 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne analogeingang 6sl3211-0ab22-2aa0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 2,2kw; vt: 2,2kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +50 deg c without bop without rs485-interface 6sl3211-0ab22-2aa1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz analogeingang ct: 2,2kw; vt: 2,2kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+50grd c ohne bop ohne rs485-interface 6sl3211-0ab22-2ab0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 2,2kw; vt: 2,2kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +50 deg c without bop without an 6sl3211-0ab22-2ab1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 2,2kw; vt: 2,2kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+50grd c ohne bop ohne analog 6sl3211-0ab22-2ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 2,2kw; vt: 2,2kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +50 deg c without bop without rs485-interface 6sl3211-0ab22-2ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 2,2kw; vt: 2,2kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+50grd c ohne bop ohne rs485-interface 6sl3211-0ab22-2ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 2,2kw; vt: 2,2kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +50 deg c without bop without analog in 6sl3211-0ab22-2ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 2,2kw; vt: 2,2kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+50grd c ohne bop ohne analogeingang 6sl3211-0ab23-0aa0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 3,0kw; vt: 3,0kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without rs485-interface 6sl3211-0ab23-0aa1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz analogeingang ct: 3,0kw; vt: 3,0kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne rs485-interface 6sl3211-0ab23-0ab0 sinamics g110 - cpm110 ac-drive,built in class a filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 3,0kw; vt: 3,0kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without an 6sl3211-0ab23-0ab1 sinamics g110 - cpm110 ac-drive, mit integr. filter a 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 3,0kw; vt: 3,0kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne analog 6sl3211-0ab23-0ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 3,0kw; vt: 3,0kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without rs485-interface 6sl3211-0ab23-0ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 3,0kw; vt: 3,0kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne rs485-interface 6sl3211-0ab23-0ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 3,0kw; vt: 3,0kw ct-overload: 150% 60s 181 x 184 x 152 (hxwxd) protection ip20 ambient temp -10 to +40 deg c without bop without analog in 6sl3211-0ab23-0ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 3,0kw; vt: 3,0kw ct-ueberlast: 150% 60s 181 x 184 x 152 (hxbxt) schutzart ip20 umgebungstemperatur -10+40grd c ohne bop ohne analogeingang 6sl3211-0kb11-2ba0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 0,12kw; vt: 0,12kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs 6sl3211-0kb11-2ba1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,12kw; vt: 0,12kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10 6sl3211-0kb11-2bb0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,12kw; vt: 0,12kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c with 6sl3211-0kb11-2bb1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,12kw; vt: 0,12kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgeb 6sl3211-0kb11-2ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 0,12kw; vt: 0,12kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs485-int 6sl3211-0kb11-2ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,12kw; vt: 0,12kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10+50grd c 6sl3211-0kb11-2ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,12kw; vt: 0,12kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop 6sl3211-0kb11-2ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,12kw; vt: 0,12kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstempe 6sl3211-0kb12-5ba0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 0,25kw; vt: 0,25kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs 6sl3211-0kb12-5ba1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,25kw; vt: 0,25kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10 6sl3211-0kb12-5bb0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,25kw; vt: 0,25kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c with 6sl3211-0kb12-5bb1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,25kw; vt: 0,25kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgeb 6sl3211-0kb12-5ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 0,25kw; vt: 0,25kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs485-int 6sl3211-0kb12-5ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,25kw; vt: 0,25kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10+50grd c 6sl3211-0kb12-5ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,25kw; vt: 0,25kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop 6sl3211-0kb12-5ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,25kw; vt: 0,25kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstempe 6sl3211-0kb13-7ba0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 0,37kw; vt: 0,37kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs 6sl3211-0kb13-7ba1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,37kw; vt: 0,37kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10 6sl3211-0kb13-7bb0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,37kw; vt: 0,37kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c with 6sl3211-0kb13-7bb1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,37kw; vt: 0,37kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgeb 6sl3211-0kb13-7ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 0,37kw; vt: 0,37kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs485-int 6sl3211-0kb13-7ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,37kw; vt: 0,37kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10+50grd c 6sl3211-0kb13-7ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,37kw; vt: 0,37kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop 6sl3211-0kb13-7ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,37kw; vt: 0,37kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstempe 6sl3211-0kb15-5ba0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 0,55kw; vt: 0,55kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs 6sl3211-0kb15-5ba1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,55kw; vt: 0,55kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10 6sl3211-0kb15-5bb0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,55kw; vt: 0,55kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c with 6sl3211-0kb15-5bb1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,55kw; vt: 0,55kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgeb 6sl3211-0kb15-5ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 0,55kw; vt: 0,55kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop without rs485-int 6sl3211-0kb15-5ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,55kw; vt: 0,55kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10+50grd c 6sl3211-0kb15-5ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,55kw; vt: 0,55kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +50 deg c without bop 6sl3211-0kb15-5ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,55kw; vt: 0,55kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstempe 6sl3211-0kb17-5ba0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz analog input ct: 0,75kw; vt: 0,75kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +40 deg c without bop without rs 6sl3211-0kb17-5ba1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,75kw; vt: 0,75kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10 6sl3211-0kb17-5bb0 sinamics g110 - cpm110 ac-drive,built in class b filtr 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,75kw; vt: 0,75kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +40 deg c with 6sl3211-0kb17-5bb1 sinamics g110 - cpm110 ac-drive, mit integr. filter b 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,75kw; vt: 0,75kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgeb 6sl3211-0kb17-5ua0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz analog input ct: 0,75kw; vt: 0,75kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +40 deg c without bop without rs485-int 6sl3211-0kb17-5ua1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz analogeingang ct: 0,75kw; vt: 0,75kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstemperatur -10+40grd c 6sl3211-0kb17-5ub0 sinamics g110 - cpm110 ac-drive, without filter 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protocol) ct: 0,75kw; vt: 0,75kw ct-overload: 150% 60s 150 x 90 x 101 (hxwxd) protection ip20 without heatsink ambient temp -10 to +40 deg c without bop 6sl3211-0kb17-5ub1 sinamics g110 - cpm110 ac-drive, ungefiltert 1ac200-240v +10/-10% 47-63hz rs485-interface (uss-protokoll) ct: 0,75kw; vt: 0,75kw ct-ueberlast: 150% 60s 150 x 90 x 101 (hxbxt) ip20; mit flachem kuehlkoerper; nur fuer kuehlplattenmontage umgebungstempe 6sl3225-0se17-5ua0 frequenzumrichter fuer et 200s leistungsteil ipm25 modulbreite 65 mm 3ac380-480v +10/-15% 47-63hz leistung 0,75 kw ueberlast 150% 60s, 200% 3s netzrueckspeisung erweiterbar mit brake control modul option: ext. emv-filter (kl. a) 6sl3225-0se22-2ua0 frequenzumrichter fuer et 200s leistungsteil ipm25 modulbreite 130 mm 3ac380-480v +10/-15% 47-63hz leistung 2,2 kw ueberlast 150% 60s, 200% 3s netzrueckspeisung erweiterbar mit brake control modul option: ext. emv-filter (kl. a) 6sl3225-0se24-0ua0 frequenzumrichter fuer et 200s leistungsteil ipm25 modulbreite 130 mm 3ac380-480v +10/-15% 47-63hz leistung 4,0 kw ueberlast 150% 60s, 200% 3s netzrueckspeisung erweiterbar mit brake control modul option: ext. emv-filter (kl. a) 6sl3244-0sa00-1aa0 frequenzumrichter fuer et 200s regelungsbaugruppe modulbreite 15 mm kombinierbar mit leistungsteil ipm25 regelungsarten: u/f,fcc,slvc, vc mit geber, moment-regelung eing. motorgeber: htl unipolar eing. motortemperatur: ptc/kty rs232: ibn-tool starter 6sl3244-0sa01-1aa0 frequenzumrichter fuer et 200s regelungsbaugruppe safety integrated modulbreite 15 mm kombinierbar mit leistungsteil ipm25 regelungsarten: u/f,fcc,slvc, vc mit geber, moment-regelung eing. motorgeber: htl unipolar eing. motortemperatur: ptc/kty rs232 6sl3254-0am00-0aa0 mmc-parameterspeicher fuer et 200s fc 6sl3255-0aa00-2aa0 sinamics g110 pc-inverter connection kit 6sl3255-0aa00-4ba0 sinamics g110 basic operator panel (bop) 6sl3261-1ba00-0aa0 sinamics g110 din rail mounting kit size 1, fs a 6sl3261-1bb00-0aa0 sinamics g110 montageadapter din-schiene groesse 2, fuer fs b 6sl3271-0ca00-0ag0 sinamics g110 commissioning tool and docu cd-rom, multi language for cpm110 6sl3298-0aa11-0ap0 sinamics g110 operating instructions cpm110 in german 6sl3298-0aa11-0bp0 sinamics g110 operating instructions cpm110 in english 6sl3298-0aa11-0cp0 sinamics g110 operating instructions cpm110 in italian 6sl3298-0aa11-0dp0 sinamics g110 operating instructions cpm110 in french 6sl3298-0aa11-0ep0 sinamics g110 operating instructions cpm110 in spain 6sl3298-0ba11-0ap0 sinamics g110 paramter list cpm110 in german 6sl3298-0ba11-0bp0 sinamics g110 paramter list cpm110 in english 6sl3298-0ba11-0cp0 sinamics g110 paramter list cpm110 in italian 6sl3298-0ba11-0dp0 sinamics g110 paramter list cpm110 in french 6sl3298-0ba11-0ep0 sinamics g110 paramter list cpm110 in spain 6sl3300-1ae31-3aa0 sinamics braking module eingang: dc 600v ausgang: 125 kw/15s fuer chassisgeraet 6sl3300-1ae32-5aa0 sinamics braking module eingang: dc 600v ausgang: 250 kw/15s fuer chassisgeraet gx 6sl3300-1ae32-5ba0 sinamics braking module eingang: dc 600v ausgang: 250 kw/15s fuer chassisgeraete h und j 6sl3300-1ah31-3aa0 sinamics braking module eingang: dc 1035v ausgang: 125 kw/15s fuer chassisgeraet 6sl3300-1ah32-5aa0 sinamics braking module eingang: dc 1035v ausgang: 250 kw/15s fuer chassisgeraet gx 6sl3300-1ah32-5ba0 sinamics braking module eingang: dc 1035v ausgang: 250 kw/15s fuer chassisgeraete hx und jx 6sl3300-7te32-6aa0 sinamics active interface module fuer 3ac 380-480 v, 50/60 hz 132 kw und 160 kw active line module interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7te33-8aa0 sinamics active interface module fuer 3ac 380-480 v, 50/60 hz 235 kw active line module interne luftkuehlung 6sl3300-7te35-0aa0 sinamics active interface module fuer 3ac 380-480 v, 50/60 hz 300 kw active line module interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7te38-4aa0 sinamics s120 active interface module fuer active line module 380/500kw 3ac 380-480v, 50/60hz, 840a typenleistung: 500kw einbaugeraet ip00 interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7te41-4aa0 sinamics s120 active interface module fuer active line module 630/900kw 3ac 380-480v, 50/60hz, 1405a typenleistung: 900kw einbaugeraet ip00 interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7th35-8aa0 sinamics s120 active interface module fuer active line module 560kw 3ac 660-690v, 50/60hz, 575a typenleistung: 560kw einbaugeraet ip00 interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7th37-4aa0 sinamics s120 active interface module fuer active line module 800kw 3ac 660-690v, 50/60hz, 735a typenleistung: 800kw einbaugeraet ip00 interne luftkuehlung inkl. drive-cliq leitung 6sl3300-7th41-3aa0 sinamics s120 active interface module fuer active line module 1100/1400kw 3ac 660-690v, 50/60hz, 1270a typenleistung: 1400kw einbaugeraet ip00 interne luftkuehlung inkl. drive-cliq leitung
|